Your new shower needs a way to dry out.
A bathroom can look finished while moisture still hangs in the air. If you are opening the walls or replacing the shower, it is a good time to check where the fan sends that air and whether it moves enough of it.
During a bathroom remodel, check that the exhaust fan moves enough air and vents directly outdoors. For an intermittently operated fan in a bathroom under 100 square feet, the Home Ventilating Institute recommends at least 50 CFM or roughly 1 CFM per square foot, whichever is greater. Bigger bathrooms call for a fixture-based review. A fan that makes noise but exhausts into an attic does not solve the moisture problem.
Steam has to leave the room
A hot shower puts moisture into the air. It can settle on the mirror, ceiling, paint and cooler surfaces. The EPA’s bathroom remodeling guidance says ventilation helps remove that moisture and advises checking whether the existing fan actually exhausts enough air outdoors. Hearing a motor turn is not the same as confirming airflow.
The same EPA guide says wet walls should keep water out of cavities and leaks should be repaired. Those are separate jobs from removing humid air. New tile cannot repair a hidden leak, and a stronger fan cannot waterproof a bad shower connection.
Moisture source
Find out whether dampness comes from showers, a plumbing leak, condensation, or more than one cause.
Air route
Confirm the fan’s duct terminates outside, not in an attic or another part of the house.
Daily use
Choose a fan and control people will actually use, then keep the grille clean.
How large should your bathroom fan be?
The Home Ventilating Institute’s intermittent ventilation guidance recommends about 1 CFM per square foot for bathrooms under 100 square feet, with a 50 CFM minimum. It advises a fixture-based calculation for larger bathrooms. This is a selection guide, not a measurement of airflow in your installed duct or a statement of Greensboro’s code requirements.
Illustrative HVI minimum for an intermittently operated fan in a bathroom under 100 square feet. Installed performance depends on the fan and duct layout.
For rooms over 100 square feet, HVI adds the airflow associated with the fixtures: 50 CFM each for a toilet, shower or bathtub, and 100 CFM for a jetted tub. For example, a room with a shower and toilet leads to a 100 CFM fixture sum. Enclosed toilet rooms and tall ceilings can change the plan. Have the installer review the actual room and local requirements.
Why not just buy the biggest fan? Duct size, bends, distance to an exterior termination, available replacement air and sound all matter. The rating on a box is not a guarantee of what the installed system will deliver.
Outside means outside
The EPA says bathroom exhaust should go directly outdoors, not into an attic or another room. If the existing ceiling is being opened, have the contractor confirm where the duct terminates and whether it is connected, intact and suited to the new fan.
Air also has to enter the bathroom to replace what the fan removes. HVI’s guidance discusses clearance below the bathroom door for replacement air. A tightly sealed door can work against a fan, while a leaky duct or long restrictive route can limit delivered airflow. The details need to be checked together.
If your remodel includes a new walk-in shower or a larger wet area, discuss ventilation while finalizing the shower plan. Our articles on tub-to-shower conversion and curbless showers cover the floor and waterproofing decisions.
Quiet operation and controls are part of the plan
Bathroom fan noise is measured in sones. HVI says 1.0 sone or less is a quiet choice. ENERGY STAR’s fan criteria include tested airflow, energy efficiency and sound levels. Review both the airflow rating and the noise rating, especially if a loud existing fan gets switched off early.
Timer
A timer keeps the fan running after the shower without asking someone to remember to return and switch it off. HVI recommends ventilation continue at least 20 minutes after bathroom use.
Humidity control
An automatic control can respond to moisture. Its settings and placement still need to suit the room and the household.
Exterior route
A quiet fan with poor ducting will still perform poorly. Ask about the whole route rather than buying by CFM alone.
Installation instructions and the electrician’s plan also matter when combining a fan with lighting or a switch change. If the fan is placed over a shower, confirm the selected model is approved for that location, as HVI advises.
Condensation or a leak?
If the mirror fogs and clears after ventilation, the problem may be airborne moisture. If a stain grows around a shower corner, paint blisters in one spot or flooring stays soft, do not assume the fan is the only issue. Ask the contractor to inspect plumbing, grout and sealant, wall assembly and the subfloor where the evidence points.
During demolition, damaged material should be investigated before it is covered. The EPA’s remodeling guidance specifically separates leak repairs, wet-wall construction and ventilation. A good bathroom plan addresses each cause that is present.
Photos of stains or recurring damp areas taken before demolition can help guide the on-site inspection. Let the contractor know where water appears, whether it happens only after showering, and what is on the other side of the wall.
Check the permit scope for fan and wiring changes
The City of Greensboro’s residential construction guidance describes separate electrical and mechanical trade permits for work in those systems. The exact requirements depend on whether the project is a simple replacement, a relocated fan, new ducting or wiring, or part of a larger remodel. Ask who will obtain any required permits and schedule inspections for the actual design.
Put it in the estimate: Fan model and rated CFM, duct route and exterior termination, switch or control, electrical work, wall or ceiling repair, permit responsibility and a plan to confirm that the installed fan moves air.
What should you ask before approving the remodel?
- Where does the present fan exhaust, and is the duct connected all the way outside?
- What is the bathroom’s floor area, ceiling height and fixture count?
- What airflow and sound ratings does the proposed fan have?
- Is the location appropriate for the fan model and the shower layout?
- Will a timer or humidity control be included?
- What will be done if demolition reveals a leak or damp framing?
- Will the fan, duct, wiring, permits, patching and final test all appear in writing?
If you are gathering bids, our guide to comparing bathroom remodel quotes helps you check whether each proposal covers the same work. See our bathroom project gallery and Greensboro bathroom remodeling services for more context.
Bathroom exhaust fan questions
What size fan does a 70-square-foot bathroom need?
Using HVI’s guide for an intermittently operated fan in a bathroom under 100 square feet, about 70 CFM is the starting point. A contractor should assess the duct, ceiling, room layout and applicable local requirements before choosing the unit.
Can my bathroom fan vent into the attic?
No. EPA guidance says a bathroom fan should exhaust directly outdoors, not into an attic or another space inside the house.
Does a fan fix a leaking shower?
No. Ventilation helps remove humid air, but a plumbing or waterproofing leak must be located and repaired. Both issues can exist at the same time.
How long should the fan run after a shower?
HVI recommends a control that continues ventilation for a minimum of 20 minutes after bathroom use. The time needed in a particular room also depends on moisture load and actual airflow.
Will replacing the fan require a permit in Greensboro?
It depends on the exact work. Electrical, mechanical or other remodeling changes may require permits. Confirm the scope with the city and the contractor before work begins.
Sources and further reading
- Home Ventilating Institute, How Much Ventilation Do I Need?, bathroom airflow and controls.
- Home Ventilating Institute, Bathroom Exhaust Fans, fan performance and noise guidance.
- U.S. EPA, Remodeling Your Home and Indoor Air Quality, bathroom moisture, outdoor exhaust and water management.
- ENERGY STAR, Ventilation Fans Key Product Criteria, tested airflow and sound.
- City of Greensboro, Residential Construction, permit overview.